Conjugate/Block Buffers

D Jones djones at SCRI.SARI.AC.UK
Fri Feb 2 09:14:11 EST 1996


Vigfrid Ness wrote:-
> 
> My comment is: Have you tried the NAD/H amplification system for AP-conjugates.
> My own experience with it isn't the best - the system was too sensitive when
> it came to background noice but I know about people in Wageningen who has
> had good experience with it for detection of plant pathogens.
> 
 Thanks for your comment. I have in fact tried the NAD/H amplification
system, and my experience was exactly the same as yours. The situation
was even worse when I tried to use tuber sap as opposed to leaf sap. I
have also used a luminescence based assay, which did actually prove to
be about 10 x more sensitive at it's best, but the Titanium oxide plates
I purchased from Dynatech were very unreliable and tended to go of over
time! 
	Has anyone else had any similar problems?  

				Dave
D.A.C. Jones
S.C.R.I.
Virology
Invergowrie
Dundee
DD2 5DA

e-mail: djones at scri.sari.ac.uk