gt7680b at prism.gatech.edu (Paul Kenneth Farmer) wrote:
>Dear Netters:
>
> I have tried affinity purifying polyclonal antibodies using Affi-Gel
>10, but unfortunately the elution using acidic, basic, or chaotropic
>conditions failed to remove most of the bound antibodies or at least had
>inactivated them. I am considering three approaches: (1) Inverting the
>column and eluting in the opposite direction to prevent antibodies from
>dissociating and then reassociating with the bound ligand; (2) Using a
>batch method instead of column purification; and (3) Using electroelution
>of bound antibodies off of the column. My best success to date has been
>the straight acid elution using a glycine-HCl buffer, pH 2.5. However, the
>activity and specificity of the eluted antibodies were still unacceptable.
>
> Does anyone have any suggestions on how to improve this procedure? In
>particular, has anyone tried electroelution coupled with inverting the
>column so as to place the immobilized antibodies closer to the anode?
>
> Any suggestions would be greatly appreciated!!!!
>
> My E-Mail address is: gt7680b at prism.gatech.edu
>
>
Add Urea to your elution buffer... 2M
Martin Blankfard
Kirkegaard and Perry Laboratories
Mblank at kpl.coml