deblocking
adavies at vax.path.ox.ac.uk
adavies at vax.path.ox.ac.uk
Fri Nov 20 04:42:36 EST 1992
In article <19NOV92.16440280 at wums.wustl.edu>, wetsel_r at wums.wustl.edu writes:
> I assume that the oligo has been deprotected and off the column? If so, I
> would assume that they are currently in NH4-OH. Deprotection is then easy.
> We have our oligos in 4ml Wheaton vials available from VWR/Fisher which fit
> nicely into a heating block. Heat them overnight at 60'C. It can be done
> in an eppendorf tube as well, in fact there is probably no reason why
> deprotection couldn't be done in a 60'C water bath as long as absolute care
> is taken not to get any water mixed into the oligo.
Yep, we do just this.
Anthony Davies
Institute of Virology
Oxford UK
More information about the Methods
mailing list