protein concentrating/desalting

donald seto don at
Wed Feb 17 10:43:48 EST 1993

In article <9302171525.AA12166 at> bsh at MED.PITT.EDU (Basavaraju Shankarappa) writes:
>	I have used one small trick that might be of some help in reducing
>your loss in dialysis.  Instead of loading a dialysis tubing with the 
>sample, cut out a piece of the dialysis tubing, wash it as usual, then
>slit it so that you now have a dialysis sheet.  You can now float this
>dialysis membrane sheet on a petridish filled with the buffer you want
>it dialysed against.  
>	Now place about 50-100 ul of your sample as a drop on this floating
>piece and let it sit for about an hour or less.  You can carefully draw up
Millipore also sells a filter/membrane for this's a little more
rigid than the dialysis membrane, and perhaps less susceptible to sinking!