sma I chewing back - any suggestions?

txpljfg at UABCVSR.CVSR.UAB.EDU txpljfg at UABCVSR.CVSR.UAB.EDU
Thu Aug 11 12:02:59 EST 1994


I have had trouble in the past with sma I chewing back and causing
difficulties with blunt-end cloning.  I found that this problem was
highly lot dependent even from companies like Gibco/BRL which tend to
sell high quality reagents.  Therefore, I suggest that you get sma I
from several different companies/lots and try your protocol again

==============================================================================
James F. George, Ph.D.              "Back off man, I'm a scientist"
Department of Surgery                --Bill Murray
University of Alabama at Birmingham
205-934-4261 voice
txpljfg at uabcvsr.cvsr.uab.edu
===============================================================================