Darren M. Stauth (stauth at crunch.usgmrl.ksu.edu) wrote:
: I heard some discussion earlier about using multiple primers (more than
: two) in PCR screening. So I tried it out and it worked beautifully. I
: tested two cocktails with a total of 7 primers (one common to all of my
: samples and two sets of six unique primers). I used the program Amplify to
: make sure all primers were compatible. Each primer was at a final
: concentration of 10pmol for a 10ul reaction (used a hot-air termo-cycler).
: I made sure to have positive and negative controls for each of the 12
: unique primers. It was a total success! A couple artifacts from
: misannealing do to the high concentration of primers were observed, but
: they were easily distinguished from true positives. This means a major
: saving of time and effort for me. Just thought I'd pass on the news to
: anyone interested. Feel free to write for any info.
Where does this program Amplify come from?
#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%
% #
# Dr. Michael Cooley Practice Random Kindness %
% mbcooley at ucdavis.edu and Senseless Acts of Beauty #
# %
%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#%#
More information about the Methods