Sticky Sequencing gel
B.L.Cohen
gbga13 at udcf.gla.ac.uk
Fri Jun 16 11:39:04 EST 1995
In article <3rpuec$vo at tali.hsc.colorado.edu>,
oshiro_G at defiance.hsc.colorado.edu (Guy Oshiro) wrote:
>
> >I took the saran wrap off, do I HAVE to do this to get a signal???
>
> You definitely have to do this if you are working with S35. The signal
> is weak enough that saran wrap alone is effective in blocking the soft
> beta particles.
>
This is not true. Surprisingly, Saran makes not more than ca. 50%
difference to signal strength.
--
Dr Bernard L. Cohen Phone (+44) (0)41 339 8855 ext. 5103/5101
Genetics Dept., Fax 330 5994
University of Glasgow
Church St.,
Glasgow G11 5JS
Scotland, UK.