Sticky Sequencing gel

B.L.Cohen gbga13 at udcf.gla.ac.uk
Fri Jun 16 11:39:04 EST 1995


In article <3rpuec$vo at tali.hsc.colorado.edu>,
oshiro_G at defiance.hsc.colorado.edu (Guy Oshiro) wrote:

> 
> >I took the saran wrap off, do I HAVE to do this to get a signal???
> 
> You definitely have to do this if you are working with S35.  The signal
> is weak enough that saran wrap alone is effective in blocking the soft
> beta particles.
> 
This is not true.  Surprisingly, Saran makes not more than ca. 50%
difference to signal strength.  
-- 
Dr Bernard L. Cohen          Phone (+44) (0)41 339 8855 ext. 5103/5101
Genetics Dept.,              Fax               330 5994
University of Glasgow
Church St.,
Glasgow G11 5JS
Scotland, UK.



More information about the Methods mailing list