looking for a method to strip gel plates
H. ROYCHOWDHURY
hroychow at NMSU.EDU
Wed Aug 28 10:03:12 EST 1996
On 27 Aug 1996, brad swanson wrote:
> Hi,
> I use a BioRad sequencing gel apparatus to run out microsatellite DNA and
> I coat one of the plates with Sigmacote to make it 'slick'. I have noticed
> recently that the gels are starting to have difficultly staying on one
> plate. Someone suggested that I need to strip the plates of the Sigmacote
> b/c the plates become 'overcoated' over time. Does anyone have a recipe
> for a stripping reagent? Thanks in advance! Cathy Mossman
>
>
Soak the plate(s) in 0.1N NaOH overnight.
>>>>>>>>>>>>>>>>>>>>>>>>>>>
Dr. Hiranya S. Roychowdhury
Plant Genetic Engineering Lab.
Box 3GL, NM State Univ.
Las Cruces, NM 88003
Phone: (505) 646-5785
hroychow at nmsu.edu
<<<<<<<<<<<<<<<<<<<<<<<<<<<
More information about the Methods