problems with primer dimer!
Wolfgang Schechinger
wolfsc at ibms.sinica.edu.tw
Mon Aug 27 08:48:00 EST 2001
Babett,
Probably happens when freeze thawing primers for many
times.
Try melting the primers 10 min or more at 94 degC, then put
the vial into ice water. This procedure should break up all
primer primer interactions.
If not, order new ones and aliquot them after dilution into
convenient fractions of e.f. 25 ul each. That's probably cheaper
than spending days in finding the true cause. Where do you
get your oligos from?
Wolfgang
> Hope somebody can help me.
> We investigated gene expression using PCR without any problems.
> Since last week, we suddenly have a lot of primer dimers and
> problems with the right size band. How can we solve the problem
> with the excess of primer dimers??
>
> Thanks in advance
>
> Andreas
>
>
>
>