On Fri, 27 Jul 2001, Warren Gallin wrote:
> Hi folks,
> I am trying to do a Western blot on a set of cell lines and am trying
> to keep the protein concentration as high as possible. The problem is
> that the DNA released on boiling in SDS makes the sample impossible to
> pipette accurately.
> Aside from dilution, does anyone have a way to get the viscosity of
> this kind of extract down to a workable level?
>
> Thanks.
>
> Warren Gallin
Dear Warren,
I had the same problem myself today. My solution was to suck
the sample (250microlitre volume) through a narrow needle five or 10
times. Be careful not to make foam. If you do have a sonicator maybe
Louis Hom's advise is best though. Mike