20% is high for acrylamide. Have you considered a tricine gel? If you
absolutely need sds page 4c @ 18mA overnight should work fine. Also, if
you are using a premixed concentrate for your running buffer the pH can
be affected by your water source.
K
 -----Original Message-----
From: methods-bounces from oat.bio.indiana.edu
[mailto:methods-bounces from oat.bio.indiana.edu] On Behalf Of yan sun
Sent: Sunday, April 27, 2008 11:39 PM
To: Haviland, David L
Cc: Methods from magpie.bio.indiana.edu
Subject: Re: Page gel


 run 20% gel 4w around 10 hours, but the ladder is diffused, I mean the
band is really wide"(
did it happen to you?
if you run under very low watage, it is easy to diffuse.



On 4/27/08, Haviland, David L <David.L.Haviland from uth.tmc.edu> wrote:
>
>
> The reasons you cite is exactly why I always ran my gels on constant
amps
> rather than volts.   For a 10% SDS-PAGE I could start it at 5 pm and
by 9 am
> the next morning it was about 3 cm from the bottom.   Even during the
day I
> never ran them above 25 mA without some form of cooling else they'd
"smile"
> and make interpretation a bit problematic.    In my hands, slower was
always
> better.
>
> David
>
> -----Original Message-----
> From: methods-bounces from oat.bio.indiana.edu on behalf of yan sun
> Sent: Sat 4/26/2008 6:38 PM
> To: Methods from magpie.bio.indiana.edu
> Subject: Page gel
>
> Dear all,
> I got a question about PAGE electrophoresis gel to confirm.
> When we mention that proper volts condition for running a gel is
around
> 20V/cm.
> For eample, my gel is 20 cm, which means that proper Volts is ~400V?
Am I
> right?
> If the volts is toooo high, the gel might toooo hot to get good
> resolution,
> right?
> Thx a lot!!!!
>
> Frances
> --
> Y. F.S.
> _______________________________________________
> Methods mailing list
> Methods from net.bio.net
> http://www.bio.net/biomail/listinfo/methods
>
>


-- 
Y. F.S.
_______________________________________________
Methods mailing list
Methods from net.bio.net
http://www.bio.net/biomail/listinfo/methods

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email 
______________________________________________________________________

Please consider the environment before printing this e-mail



This email and any files transmitted with it are confidential and
may be legally privileged and are intended solely for the use of
the individual or entity to whom they are addressed. If you are 
not the intended recipient please note that any disclosure, 
distribution, or copying of this email is strictly prohibited and may 
be unlawful.  If received in error, please delete this email and any 
attachments and confirm this to the sender.

www.shire.com



More information about the Methods mailing list