NCS Strict bug
Axel T. Brunger
brunger at LAPLACE.CSB.YALE.EDU
Sun Nov 10 16:49:30 EST 1996
This is a precision problem when entering the matrix. Enter the
rotation
operator in terms of spherical polar or Euler angles.
Axel Brunger
Xiaozhou Liu wrote:
>
> Dear Xplorers,
>
> When I use NCS STRICT(XPLOR3.1) in my refinement, I meet with a problem as
> following.
> -----------------------
> X-PLOR> ncs strict
> NCS-strict> xncsrel
> SKEW TRANSFORMATION HAS NOT BEEN GIVEN, ASSUMING IDENTITY
> XNCS> matrix=(-0.999547 -0.030109 0.000073)
> MATRix-second-row= (-0.030109 0.999535 -0.004774)
> MATRix-third-row= ( 0.000071 -0.004774 -0.999989)
> XNCS>
> XNCS> translation=(55.7093 1.1269 120.6352)
> XNCS> end
> NCS-strict>
> NCS-strict> ?
>
> THERE ARE 2 NCS RELATIONS DEFINED, INCLUDING IDENTITY
> The first 2 will be used for structure factor calculations;
> all will be used for non-bonded interactions.
> The operators give the NCS related atoms in the
> same frame as the input coordinates:
>
> RELATION NO. 1:
>
> Rotation matrix =
> 1.000000 0.000000 0.000000
> 0.000000 1.000000 0.000000
> 0.000000 0.000000 1.000000
> Corresp. Eulerian angles (theta1,theta2,theta3) 0.0000 0.0000 0.0000
> Corresp. spherical polar angles (psi,phi,kappa) 0.0000 0.0000 0.0000
> Corresp. rotation angle 0.0000 about axis 0.0000 1.0000 0.0000
> Corresp. quaternions 1.0000 0.0000 0.0000 0.0000
>
> Translation vector = ( 0.0000 0.0000 0.0000)
>
> RELATION NO. 2:
>
> Rotation matrix =
> -0.999547 -0.030109 0.000073
> -0.030109 0.999535 -0.004774
> 0.000071 -0.004774 -0.999989
> %ROTMAT-ERR: inconsistent T1,T2,T3= 0.0000E+00 179.7 180.0
>
> ROT =
> -0.999547 -0.030109 0.000073
> -0.030109 0.999535 -0.004774
> 0.000071 -0.004774 -0.999989
>
> ROT2 =
> -1.000000 0.000000 0.000000
> 0.000000 0.999989 -0.004690
> 0.000000 -0.004690 -0.999989
> %MATROT-ERR: Error in internal consistency check
> %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
> BOMLEV= 0 reached. Programexecution will be terminated.
> %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
> Subroutine DIE called . Terminating
> --------------------------------------------------------------------------
> Does anyone has seen the same problem? I want to know if it can be solved
> and how to solve. Or do I have to get a new version of XPLOR? Any help of
> yours will be greatly appreciated.
>
> Xiaozhou.
>
> +--------------------------------------+
> | Xiaozhou Liu |
> | Dept. of Physiology and Biophysics |
> | College of Life Science |
> | Peking University |
> | Beijing, 100871 |
> | P.R.China |
> | Email:liuxz at iris.lsc.pku.edu.cn |
> +--------------------------------------+
--
=======================================================================
| Axel T. Brunger Dept. Molecular Biophysics and Biochemistry|
| Professor/Investigator Bass Center, 266 Whitney Avenue |
| Office: 203-432-6143 Howard Hughes Medical Institute/Yale Univ. |
| FAX: 203-432-6946 New Haven, CT 06520, USA. |
| http://xplor.csb.yale.edu/~brunger |
| mailto://brunger@laplace.csb.yale.edu |
=======================================================================
More information about the X-plor
mailing list