unread mercury
Axel T. Brunger
brunger at LAPLACE.CSB.YALE.EDU
Mon Sep 2 21:05:35 EST 1996
Your definition of the chemical atom type of mercury probably
doesn't match chemical HG+* . Do a
vector show elem ( chemical ) ( <select mercury atom here>)
Note, that complete scattering tables are avaiable in the
developmental version of X-PLOR (file $XTALLIB/scatter.lib for
normal scattering, and two anomalous scattering libraries).
Axel Brunger
A Rashid wrote:
>
> Dear xplorers,
>
> I have been doing refinments on my protein (rigid body, positional, etc.)
> and I just noticed that the program does not seem to recognize an atom in the
> structure, namely a mercury. The output from the check,inp ( or any other routine
> for that matter) is:
>
> ==================================
> XREFINE> SCATter ( chemical C* )
> SELRPN: 1468 atoms have been selected out of 2773
> a1= 2.31000 20.8439 1.02000 10.2075 1.58860 .568700 .865000 51.6512 .215600
> XREFINE> SCATter ( chemical N* )
> SELRPN: 392 atoms have been selected out of 2773
> a1= 12.2126 .005700 3.13220 9.89330 2.01250 28.9975 1.16630 .582600 -11.529
> XREFINE> SCATter ( chemical O* )
> SELRPN: 409 atoms have been selected out of 2773
> a1= 3.04850 13.2771 2.28680 5.70110 1.54630 .323900 .867000 32.9089 .250800
> XREFINE> SCATter ( chemical S* )
> SELRPN: 4 atoms have been selected out of 2773
> a1= 6.90530 1.46790 5.20340 22.2151 1.43790 .253600 1.58630 56.1720 .866900
> XREFINE> SCATter ( chemical P* )
> SELRPN: 0 atoms have been selected out of 2773
> a1= 6.43450 1.90670 4.17910 27.1570 1.78000 0.52600 1.49080 68.1645 1.11490
> XREFINE> SCATter ( chemical FE* )
> SELRPN: 2 atoms have been selected out of 2773
> a1= 11.1764 4.61470 7.38630 0.30050 3.39480 11.6729 0.07240 38.5566 0.97070
> XREFINE> SCATter ( chemical HG+* )
> SELRPN: 0 atoms have been selected out of 2773
> a1= 29.5641 1.21152 18.0600 7.05639 12.8374 0.28473 6.89912 20.7482 10.6268
>
> ==================================
>
> at the end you can see that the program thinks that there are 0 HG+ atoms. The
> program recognizes all the rest including the FE on the HEM.
> If anyone has an idea as to why this is happening please let me know.
> Thank you in advance and have a nice labor day weekend.
>
> Sincerely,
> Ali
--
=======================================================================
| Axel T. Brunger Dept. Molecular Biophysics and Biochemistry|
| Professor/Investigator Bass Center, 266 Whitney Avenue |
| Office: 203-432-6143 Howard Hughes Medical Institute/Yale Univ. |
| FAX: 203-432-6946 New Haven, CT 06520, USA. |
| http://xplor.csb.yale.edu/~brunger |
| mailto://brunger@laplace.csb.yale.edu |
=======================================================================
More information about the X-plor
mailing list