zero dist.
liuxz at PUBMS.PKU.EDU.CN
liuxz at PUBMS.PKU.EDU.CN
Wed Jul 29 21:00:15 EST 1998
On 29 Jul 1998, Jan Dohnalek wrote:
> Hi XPLOR users.
> I have encountered this error XPLOR gives when generating structure:
>
> %HBUILD-ERR: zero distance between atoms"WSUB123 TIP3OH2 " "MSUB34 GLU O "
> %<HBUILD>-ERR: There are zero interatomic distances.
> %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
> BOMLEV= 0 reached. Program execution will be terminated.
> %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
> Subroutine DIE called . Terminating
>
>
> I have checked several times the coordinates of those atoms
> in the files that XPLOR reads as coordinates. There is a distance
> of 2.93A between them.
> Then after I decided to delete the "WSUB123 TIP3OH2 " (water)
> the same problem appeared for another pair of atoms with
> about 3A distance from one to another.
Have you checked whether the water molecules are in the same asymmetric
unit? I think this probably leads to the problem.
-------------------------------------------------------
Xiaozhou Liu
Biophysics and Physiology Department
College of Life Science
Peking University
Beijing 100871, P.R.China
E-mail: liuxz at iris.lsc.pku.edu.cn
Telephone: +86 10 62751864
-------------------------------------------------------
More information about the X-plor
mailing list