HOW separate PCR product of 200,240,280bp
Hiranya Roychowdhury
hroychow at NMSU.EDU
Fri Jan 31 20:54:48 EST 1997
At 12:21 PM 1/31/97 -0600, u8251012 at cc.kmc.edu.tw wrote:
>Dear netter:
>I have big troubles in my labs works
>please give me some suggestion !!
>My PCR product is too close to eletro gel-separate
>is any good methods for this
>
>=========================================================
>Biochemist from taiwan,
>kaohsiung medical college
>Email: u8251012 at cc.kmc.edu.tw
>
>
>
>-------------------==== Posted via Deja News ====-----------------------
> http://www.dejanews.com/ Search, Read, Post to Usenet
>
>
I suggest you try acrylamide gels with TBE buffer. Following this, the products may be separated by electroelution etc.
Dr. Hiranya Sankar Roychowdhury
Plant Genetic Engineering Lab.
New Mexico State University
Las Cruces, NM 88003
Ph. (505) 646-5785
hroychow at nmsu.edu