> Hi,
> I was wondering if anyone had suggestions for the gentlest possible way
> to conjugate monoclonal antibodies to fluorescent tags? We are having
> difficulty with our standard Fluoroscein isothiocyanate technique, as it
> appears to be causing one antibody to lose it's specificity. Any help
> would be appreciated.
> thanx
Dear Mike,
coming across the same problem I have been using fluorescein-succinimidyl
esters. Boehringer sells some stuff called FLUOS. This however had the
disadvantage of giving somewhat more signal at longer wavelength
(when analysing FLUOS / Pe stained cells on a cytometer more
Pe - %FITC compensation was required as compared to real FITC / Pe stained
cells) - but one could live with that.
Molecular Probes has got some derivatives that have longer spacers
to avaoid this problem but I have not tried it yet.
jorg